{"id":1978,"date":"2026-10-27T09:00:20","date_gmt":"2026-10-27T09:00:20","guid":{"rendered":"https:\/\/techknowengg.com\/blog\/?p=1978"},"modified":"2026-10-19T05:57:23","modified_gmt":"2026-10-19T05:57:23","slug":"air-breather-sizing","status":"publish","type":"post","link":"https:\/\/techknowengg.com\/blog\/air-breather-sizing\/","title":{"rendered":"Air Breather Sizing: How to Match a Breather to Reservoir Volume and Pump Flow"},"content":{"rendered":"<p dir=\"ltr\">Most air breathers on Indian plant floors were never sized. They were chosen because they fitted the filler hole, or because the old one looked like that, or because the catalogue had one in stock. It works, right up until the day a pump starts whining on startup or the oil turns cloudy in the monsoon.<\/p>\n<p dir=\"ltr\">A breather is a filter with an airflow rating, and like any filter it has to be matched to a flow rate and a pressure drop. Getting that wrong does not fail loudly. It fails quietly, through cavitation, moisture ingress and contamination that your system filters then have to clean up.<\/p>\n<p dir=\"ltr\">Here is how to size one properly.<\/p>\n<h3 dir=\"ltr\">A breather is sized for a rate, not a volume<\/h3>\n<p dir=\"ltr\">The first thing to understand is that reservoir capacity alone does not tell you what breather to fit.<\/p>\n<p dir=\"ltr\">A 500 litre tank on a slow, low-flow circulation system may exchange almost no air. A 200 litre tank driving two fast cylinders may exchange thirty litres of air a minute, every minute of the shift. The tank volume is similar. The breather requirement is not.<\/p>\n<p dir=\"ltr\">What the breather has to handle is <strong>the rate at which the oil level changes<\/strong>, in both directions. Oil leaves the tank, air comes in. Oil returns, air goes out. The breather must pass that air without pulling the tank into vacuum or pushing it into pressure.<\/p>\n<p dir=\"ltr\">So the sizing question is always: what is the fastest the oil level can move, and how much pressure drop can the tank tolerate while that happens?<\/p>\n<h3 dir=\"ltr\">Step 1 &#8211; Work out the worst-case air exchange rate<\/h3>\n<h4 dir=\"ltr\">Cylinder circuits: the differential volume does the work<\/h4>\n<p dir=\"ltr\">In a circuit with double-acting cylinders, oil does not simply shuttle back and forth. A cylinder has more area on the full-bore side than on the annulus side, because the rod takes up space.<\/p>\n<p dir=\"ltr\">When the cylinder extends, more oil goes in than comes back. The difference comes out of the reservoir, and air must enter to replace it. When it retracts, the reverse happens and air is pushed out.<\/p>\n<p dir=\"ltr\">That difference is the rod volume, and the rate at which it moves is what the breather has to flow:<\/p>\n<p dir=\"ltr\"><strong>Air flow (l\/min) = rod cross-sectional area \u00d7 rod velocity<\/strong><\/p>\n<p dir=\"ltr\">Add up every actuator that can move at the same time. Simultaneous movement is the case that catches people out \u2014 each cylinder was checked individually, nobody checked the sequence where three of them extend together.<\/p>\n<h4 dir=\"ltr\">Worked example: a 200-litre power pack<\/h4>\n<p dir=\"ltr\">Take a typical industrial power pack:<\/p>\n<ul dir=\"ltr\">\n<li>Pump flow: 60 l\/min<\/li>\n<li>Reservoir: 200 litres<\/li>\n<li>Two cylinders, 100 mm bore with 56 mm rod, 500 mm stroke<\/li>\n<li>Both can extend together at 0.1 m\/s<\/li>\n<\/ul>\n<p dir=\"ltr\">Rod area works out to 0.00246 m\u00b2. At 0.1 m\/s, that is 0.000246 m\u00b3\/s, or <strong>14.8 l\/min of air per cylinder<\/strong>. With both extending together, the breather has to let in roughly <strong>30 l\/min<\/strong>.<\/p>\n<p dir=\"ltr\">Worth noting what else is happening in that same five-second extension. Oil entering the bore side runs at about 47 l\/min while only 32 l\/min returns from the annulus side. The reservoir is giving up the difference, and the suction line is working hard at the same moment. This is exactly when a restricted breather bites.<\/p>\n<h4 dir=\"ltr\">Accumulators change the answer completely<\/h4>\n<p dir=\"ltr\">If the circuit charges an accumulator, that fluid also leaves the reservoir, and it can leave fast.<\/p>\n<p dir=\"ltr\">A 20 litre accumulator filling over 30 seconds pulls 40 l\/min out of the tank on its own, on top of whatever the actuators are doing. Dump it back and the tank has to exhale the same volume just as quickly.<\/p>\n<p dir=\"ltr\">Systems with <a href=\"https:\/\/techknowengg.com\/accumulators.html\">hydraulic accumulators<\/a> in the circuit are routinely under-breathed for this reason. The breather was sized around the cylinders and nobody counted the accumulator. If you are not sure of the charge and discharge rates on your installation, that is worth establishing before you specify anything \u2014 our <a href=\"https:\/\/techknowengg.com\/accumulators-service-repair.html\">accumulator service and repair team<\/a> deals with this on site regularly.<\/p>\n<h4 dir=\"ltr\">The shortcut most engineers use, and when it is wrong<\/h4>\n<p dir=\"ltr\">Rather than calculate every actuator, many specifiers simply size the breather for <strong>the full pump flow rate<\/strong>.<\/p>\n<p dir=\"ltr\">In the example above that means sizing for 60 l\/min rather than 30 l\/min. It is deliberately conservative, and the logic is sound: in a fault condition \u2014 a burst hose, a stuck valve, a fast fill \u2014 oil can leave the reservoir at close to the pump\u2019s full output.<\/p>\n<p dir=\"ltr\">The shortcut is reasonable and it is what we would recommend for most standard industrial power packs. It stops being reasonable in two situations. On very large systems, sizing for full pump flow can push you into an unnecessarily large and expensive breather. And on systems with several large accumulators discharging together, full pump flow may actually be <em>less<\/em> than the real worst case, so the shortcut under-sizes rather than over-sizes.<\/p>\n<p dir=\"ltr\">Calculate properly when the system is large, unusual, or accumulator-heavy. Use the shortcut when it is a conventional power pack.<\/p>\n<h3 dir=\"ltr\">Step 2 &#8211; Decide how much pressure drop the tank can tolerate<\/h3>\n<p dir=\"ltr\">This is the constraint that actually determines the breather size, and it is almost always set by the pump.<\/p>\n<p dir=\"ltr\">Every pump specifies a minimum inlet pressure. Gear and vane pumps commonly need around 0.8 bar absolute. Piston pumps are usually stricter and some require a flooded or supercharged inlet. Check the datasheet for your pump rather than working from a general figure, because getting this wrong is how cavitation damage starts.<\/p>\n<p dir=\"ltr\">Whatever that budget is, the breather is not the only thing spending it. The <a href=\"https:\/\/techknowengg.com\/suction-filters.html\">suction strainer<\/a> takes a share, the suction line and fittings take a share, and static head may be helping or hurting depending on where the pump sits relative to the oil level.<\/p>\n<p dir=\"ltr\">Common industrial practice is to keep total reservoir vacuum under roughly 0.03 bar, leaving the rest of the inlet budget for the strainer and line losses. On the pressure stroke, remember the tank lid seals, sight glass and any level switch are also taking the load, so you do not want meaningful positive pressure either.<\/p>\n<h3 dir=\"ltr\">Step 3 &#8211; Match the micron rating to the finest filter in the system<\/h3>\n<p dir=\"ltr\">This one is simple and gets ignored constantly.<\/p>\n<p dir=\"ltr\"><strong>The breather should be at least as fine as the finest filter in the system.<\/strong><\/p>\n<p dir=\"ltr\">If your <a href=\"https:\/\/techknowengg.com\/return-line-filters.html\">return line filter<\/a> is 10 \u00b5m and the breather is 40 \u00b5m, you are deliberately letting 40 \u00b5m dirt into the tank and then asking the return filter to remove it. The return element loads faster, you change it more often, and in the meantime that dirt is circulating through pumps and valves.<\/p>\n<p dir=\"ltr\">Breather elements are available from 3 \u00b5m to 40 \u00b5m, in glass fibre and paper media, with absolute or nominal ratings depending on media type. A 10 \u00b5m breather on a system with 10 \u00b5m system filtration is coherent. A 40 \u00b5m breather on the same system is not.<\/p>\n<p dir=\"ltr\">One caution. Going finer is not free. A finer element at the same physical size has a higher pressure drop and less dirt-holding capacity, so it loads faster. If you step the rating down, step the element size up to compensate. More on how ratings and media interact in our range of <a href=\"https:\/\/techknowengg.com\/filter-elements.html\">hydraulic filter elements<\/a>.<\/p>\n<h3 dir=\"ltr\">Step 4 &#8211; Read the flow curve, and leave headroom<\/h3>\n<p dir=\"ltr\">Breather manufacturers publish airflow against pressure drop for each element. Find your required flow on the curve and read off the clean pressure drop.<\/p>\n<p dir=\"ltr\">Then leave room, because that figure only applies on day one.<\/p>\n<p dir=\"ltr\">As the element collects dust, pressure drop climbs. A breather sized to use its entire allowable pressure drop when clean has no service life at all \u2014 it is out of specification as soon as it starts doing its job. A sensible working rule is to select so the <strong>clean pressure drop sits at roughly a quarter of the allowable<\/strong>, which gives the element meaningful dirt-holding life before it starts restricting the tank.<\/p>\n<p dir=\"ltr\">On dusty sites \u2014 cement, foundries, crushing, anywhere with airborne silica \u2014 that headroom matters even more, and a high-capacity breather with more media area is usually cheaper over a year than a standard one changed four times as often.<\/p>\n<h3 dir=\"ltr\">Step 5 &#8211; Thermal breathing, the part everyone forgets<\/h3>\n<p dir=\"ltr\">Even a reservoir that never moves a drop of oil still breathes, because air expands and contracts with temperature.<\/p>\n<p dir=\"ltr\">Take the 200 litre tank from earlier with roughly 60 litres of air space above the oil. Cool it 25 \u00b0C overnight and it draws in about <strong>5 litres of ambient air<\/strong>, slowly, through the night.<\/p>\n<p dir=\"ltr\">Five litres sounds like nothing. The airflow rate is so low that no breather would ever restrict it. That is exactly why it gets dismissed.<\/p>\n<p dir=\"ltr\">But that air is ambient air, often humid, and it enters a tank whose walls are now cooler than the air coming in. Water condenses on the steel and runs down into the oil. It happens every night the machine is idle, and it is cumulative, which is why outdoor and intermittently used systems develop cloudy oil and surface rust while the duty cycle itself looks perfectly clean.<\/p>\n<p dir=\"ltr\">The fix is not a bigger breather. The fix is a <a href=\"https:\/\/techknowengg.com\/desiccant-filters.html\">desiccant breather<\/a>, which dries the incoming air rather than just filtering particles out of it. For marine, offshore, monsoon-exposed and intermittently operated systems, this is the single change that most reliably stops water problems.<\/p>\n<p dir=\"ltr\">If you suspect water is already in the oil, measure it before you buy anything. Our <a href=\"https:\/\/techknowengg.com\/oil-cleanliness-class-measurement.html\">on-site oil cleanliness testing service<\/a> gives you an actual cleanliness class and water content figure rather than a guess from the sight glass.<\/p>\n<h3 dir=\"ltr\">Step 6 &#8211; Match the breather type to where it lives<\/h3>\n<p dir=\"ltr\">Once the flow, pressure drop and rating are settled, the physical type follows from the environment:<\/p>\n<p dir=\"ltr\"><strong>Standard breathers<\/strong> suit general indoor industrial reservoirs in reasonably clean conditions.<\/p>\n<p dir=\"ltr\"><strong>High-capacity breathers<\/strong> handle large systems and high air exchange rates, running up to 15,000 l\/min where required.<\/p>\n<p dir=\"ltr\"><strong>Lockable and anti-splash types<\/strong> are the right choice for mobile and construction equipment, where the breather can be removed on site and where oil can slosh out over rough ground.<\/p>\n<p dir=\"ltr\"><strong>Flange-mount breathers<\/strong> give a secure, leak-proof fixing on larger industrial and power generation tanks.<\/p>\n<p dir=\"ltr\"><strong>Inline breathers<\/strong> are for the situations where direct tank mounting is not practical.<\/p>\n<p dir=\"ltr\"><strong>Desiccant breathers<\/strong> go wherever humidity, temperature swing or outdoor exposure is part of daily life.<\/p>\n<p dir=\"ltr\">Temperature range matters too. Breather elements are commonly rated from \u221230 \u00b0C to +100 \u00b0C, which covers most Indian installations, but confirm it if the tank is next to a furnace or outdoors in a cold region.<\/p>\n<p dir=\"ltr\">Finally, check the physical fit before ordering \u2014 thread or flange type, height clearance above the tank, and whether the breather doubles as the filler. Do not size the breather down to suit an existing hole. Change the adapter instead.<\/p>\n<h3 dir=\"ltr\">Where reservoir volume does come into it<\/h3>\n<p dir=\"ltr\">Tank volume still matters, just not in the way most people assume.<\/p>\n<p dir=\"ltr\">It sets how much air space exists above the oil, which determines the thermal breathing volume. It sets the dwell time for air bubbles to separate out and for heat to dissipate. And on a conventionally proportioned tank \u2014 commonly sized at three to five times pump flow per minute \u2014 it gives you a rough cross-check on whether your calculated air exchange looks sane.<\/p>\n<p dir=\"ltr\">What it does not do is tell you the breather\u2019s flow rating. That comes from how fast the oil moves, not how much of it there is.<\/p>\n<h3 dir=\"ltr\">Five things worth checking on your own tanks this week<\/h3>\n<p dir=\"ltr\"><strong>The breather is smaller than the finest filter in the system.<\/strong> Very common, easily fixed, immediately reduces load on your return and <a href=\"https:\/\/techknowengg.com\/pressure-line-filters.html\">pressure line filters<\/a>.<\/p>\n<p dir=\"ltr\"><strong>The breather was never changed.<\/strong> A breather with no replacement record is a restriction, not a filter. It also means the tank has been breathing through whatever path was easiest, usually a lid seal.<\/p>\n<p dir=\"ltr\"><strong>Nobody counted the accumulator.<\/strong> Check whether the charge rate was included in the original sizing.<\/p>\n<p dir=\"ltr\"><strong>Rod wipers are letting dirt in anyway.<\/strong> A perfect breather on a machine with worn cylinder seals is wasted money, because the rod is dragging contamination in on every retraction. If rods are weeping or scored, the <a href=\"https:\/\/techknowengg.com\/Hydraulic-Cylinder-Repairs.html\">cylinder repair and reseal service<\/a> is the fix.<\/p>\n<p dir=\"ltr\"><strong>There is no way to tell when it is blocked.<\/strong> Unlike pressure and return filters, breathers rarely carry a <a href=\"https:\/\/techknowengg.com\/clogging-indicators.html\">clogging indicator<\/a>. Fit one, or set a firm calendar interval based on how dirty the site actually is.<\/p>\n<h3 dir=\"ltr\">Getting the specification right<\/h3>\n<p dir=\"ltr\">Sizing a breather properly takes about ten minutes once you have four numbers: worst-case air exchange rate, allowable tank pressure drop, the finest filtration rating in the system, and the ambient conditions.<\/p>\n<p dir=\"ltr\">If you have those, you can specify with confidence. If you do not, give us the reservoir capacity, pump flow, cylinder and accumulator details and a note about the environment, and we will size it for you.<\/p>\n<p dir=\"ltr\">Techknow Engineering Enterprise supplies <a href=\"https:\/\/techknowengg.com\/air-breather-filters.html\">air breather filters for hydraulic tanks<\/a> across India in standard, high-capacity, lockable, anti-splash, flange-mount, inline and desiccant types, with ratings from 3 \u00b5m to 40 \u00b5m and flows to 15,000 l\/min. As an Authorised HYDAC Distributor in India, we also supply the matching <a href=\"https:\/\/techknowengg.com\/filter-elements.html\">filter elements<\/a> and <a href=\"https:\/\/techknowengg.com\/hydraulic-accessories.html\">hydraulic accessories<\/a> to complete the installation.<\/p>\n<p dir=\"ltr\"><a href=\"https:\/\/techknowengg.com\/contact.html\">Send us your reservoir and pump details<\/a> and we will come back with a sized recommendation.<\/p>\n<h3 dir=\"ltr\"><\/h3>\n<h3 dir=\"ltr\">FAQs :-<\/h3>\n<p dir=\"ltr\"><strong>Can I just use the same size breather that was on the tank before?<\/strong><\/p>\n<p dir=\"ltr\">Only if you know the original was correctly sized, and that the duty has not changed. Added cylinders, a bigger pump or a new accumulator all change the air exchange rate, and the original breather will not have anticipated them.<\/p>\n<p dir=\"ltr\"><strong>Is a finer breather always better?<\/strong><\/p>\n<p dir=\"ltr\">No. A finer element has a higher pressure drop and less dirt-holding capacity for the same physical size. Match the rating to the finest filter in your system, then size the element generously enough that the clean pressure drop is comfortable. Going finer without going bigger just means changing it more often.<\/p>\n<p dir=\"ltr\"><strong>Do I need a desiccant breather, or is a standard one enough?<\/strong><\/p>\n<p dir=\"ltr\">If the system runs continuously indoors in a dry environment, a standard breather is usually fine. If it sits idle overnight, lives outdoors, works near water, or runs through a humid monsoon season, a desiccant breather is worth the cost. Thermal breathing pulls in moist air whether the machine is running or not.<\/p>\n<p dir=\"ltr\"><strong>What happens if the breather is too small?<\/strong><\/p>\n<p dir=\"ltr\">The tank goes into vacuum when oil leaves, which reduces pump inlet pressure and can cause cavitation. On the exhale side, the tank pressurises and finds another way out, usually past a lid seal or sight glass. Both leave a path for unfiltered air to enter. A blocked or undersized breather therefore causes the exact contamination problem it was installed to prevent.<\/p>\n<p dir=\"ltr\"><strong>How often should breather elements be changed?<\/strong><\/p>\n<p dir=\"ltr\">It depends entirely on how much air passes through and how dirty that air is. A clean indoor installation may run a year. A cement plant or foundry may need quarterly changes. The honest approach is to change on condition where you can measure it, and otherwise set an interval based on the first element\u2019s appearance and adjust from there. Tracking <a href=\"https:\/\/techknowengg.com\/oil-cleanliness-class-measurement.html\">oil cleanliness<\/a> over time tells you whether the interval is right.<\/p>\n","protected":false},"excerpt":{"rendered":"<p>Most air breathers on Indian plant floors were never sized. They were chosen because they fitted the filler hole, or [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":1979,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_uag_custom_page_level_css":"","site-sidebar-layout":"default","site-content-layout":"","ast-site-content-layout":"default","site-content-style":"default","site-sidebar-style":"default","ast-global-header-display":"","ast-banner-title-visibility":"","ast-main-header-display":"","ast-hfb-above-header-display":"","ast-hfb-below-header-display":"","ast-hfb-mobile-header-display":"","site-post-title":"","ast-breadcrumbs-content":"","ast-featured-img":"","footer-sml-layout":"","ast-disable-related-posts":"","theme-transparent-header-meta":"default","adv-header-id-meta":"","stick-header-meta":"","header-above-stick-meta":"","header-main-stick-meta":"","header-below-stick-meta":"","astra-migrate-meta-layouts":"set","ast-page-background-enabled":"default","ast-page-background-meta":{"desktop":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"ast-content-background-meta":{"desktop":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"footnotes":""},"categories":[24],"tags":[29,33,26,38,25],"class_list":["post-1978","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-oil-filters","tag-air-breather-filters","tag-desiccant-filters","tag-filter-elements","tag-hydraulic-filter","tag-oil-filters"],"uagb_featured_image_src":{"full":["https:\/\/techknowengg.com\/blog\/wp-content\/uploads\/2026\/10\/Hydraulic-Equipment-Assembly-in-Modern-Workshop.webp",1746,901,false],"thumbnail":["https:\/\/techknowengg.com\/blog\/wp-content\/uploads\/2026\/10\/Hydraulic-Equipment-Assembly-in-Modern-Workshop-150x150.webp",150,150,true],"medium":["https:\/\/techknowengg.com\/blog\/wp-content\/uploads\/2026\/10\/Hydraulic-Equipment-Assembly-in-Modern-Workshop-300x155.webp",300,155,true],"medium_large":["https:\/\/techknowengg.com\/blog\/wp-content\/uploads\/2026\/10\/Hydraulic-Equipment-Assembly-in-Modern-Workshop-768x396.webp",768,396,true],"large":["https:\/\/techknowengg.com\/blog\/wp-content\/uploads\/2026\/10\/Hydraulic-Equipment-Assembly-in-Modern-Workshop-1024x528.webp",1024,528,true],"1536x1536":["https:\/\/techknowengg.com\/blog\/wp-content\/uploads\/2026\/10\/Hydraulic-Equipment-Assembly-in-Modern-Workshop-1536x793.webp",1536,793,true],"2048x2048":["https:\/\/techknowengg.com\/blog\/wp-content\/uploads\/2026\/10\/Hydraulic-Equipment-Assembly-in-Modern-Workshop.webp",1746,901,false],"web-stories-poster-portrait":["https:\/\/techknowengg.com\/blog\/wp-content\/uploads\/2026\/10\/Hydraulic-Equipment-Assembly-in-Modern-Workshop-640x853.webp",640,853,true],"web-stories-publisher-logo":["https:\/\/techknowengg.com\/blog\/wp-content\/uploads\/2026\/10\/Hydraulic-Equipment-Assembly-in-Modern-Workshop-96x96.webp",96,96,true],"web-stories-thumbnail":["https:\/\/techknowengg.com\/blog\/wp-content\/uploads\/2026\/10\/Hydraulic-Equipment-Assembly-in-Modern-Workshop-150x77.webp",150,77,true]},"uagb_author_info":{"display_name":"admin","author_link":"https:\/\/techknowengg.com\/blog\/author\/techknow\/"},"uagb_comment_info":0,"uagb_excerpt":"Most air breathers on Indian plant floors were never sized. They were chosen because they fitted the filler hole, or [&hellip;]","_links":{"self":[{"href":"https:\/\/techknowengg.com\/blog\/wp-json\/wp\/v2\/posts\/1978","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/techknowengg.com\/blog\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/techknowengg.com\/blog\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/techknowengg.com\/blog\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/techknowengg.com\/blog\/wp-json\/wp\/v2\/comments?post=1978"}],"version-history":[{"count":2,"href":"https:\/\/techknowengg.com\/blog\/wp-json\/wp\/v2\/posts\/1978\/revisions"}],"predecessor-version":[{"id":1994,"href":"https:\/\/techknowengg.com\/blog\/wp-json\/wp\/v2\/posts\/1978\/revisions\/1994"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/techknowengg.com\/blog\/wp-json\/wp\/v2\/media\/1979"}],"wp:attachment":[{"href":"https:\/\/techknowengg.com\/blog\/wp-json\/wp\/v2\/media?parent=1978"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/techknowengg.com\/blog\/wp-json\/wp\/v2\/categories?post=1978"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/techknowengg.com\/blog\/wp-json\/wp\/v2\/tags?post=1978"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}